282 research outputs found

    A side-by-side comparison of Daya Bay antineutrino detectors

    Get PDF
    The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle θ_(13) with a sensitivity better than 0.01 in the parameter sin^22θ_(13) at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties are smaller than requirements

    Contrasting Metacognitive, Social Cognitive and Alexithymia Profiles in Adults with Borderline Personality Disorder, Schizophrenia and Substance Use Disorder

    Get PDF
    Deficits in the ability to recognize and think about mental states are broadly understood to be a root cause of dysfunction in Borderline Personality Disorder (PD). This study compared the magnitude of those deficits relative to other forms of serious mental illness or psychiatric conditions. Assessments were performed using the metacognition assessment scale-abbreviated (MAS-A), emotion recognition using the Bell Lysaker Emotion Recognition Test and alexithymia using the Toronto Alexithymia Scale among adults with schizophrenia (n = 65), Borderline PD (n = 34) and Substance Use disorder without psychosis or significant Borderline traits (n = 32). ANCOVA controlling for age revealed the Borderline PD group had significantly greater levels of metacognitive capacity on the MAS-A than the schizophrenia group and significantly lower levels of metacognitive capacity than the Substance Use group. Multiple comparisons revealed the Borderline PD group had significantly higher self-reflectivity and awareness of the other's mind than the schizophrenia group but lesser mastery and decentration on the MAS-A than substance use group, after controlling for self-report of psychopathology and overall number of PD traits. The Borderline PD and Schizophrenia group had significantly higher levels of alexithymia than the substance use group. No differences were found for emotion recognition. Results suggest metacognitive functioning is differentially affected in different mental disorders

    Evolution of the Reactor Antineutrino Flux and Spectrum at Daya Bay

    Full text link
    The Daya Bay experiment has observed correlations between reactor core fuel evolution and changes in the reactor antineutrino flux and energy spectrum. Four antineutrino detectors in two experimental halls were used to identify 2.2 million inverse beta decays (IBDs) over 1230 days spanning multiple fuel cycles for each of six 2.9 GWth_{\textrm{th}} reactor cores at the Daya Bay and Ling Ao nuclear power plants. Using detector data spanning effective 239^{239}Pu fission fractions, F239F_{239}, from 0.25 to 0.35, Daya Bay measures an average IBD yield, σˉf\bar{\sigma}_f, of (5.90±0.13)×1043(5.90 \pm 0.13) \times 10^{-43} cm2^2/fission and a fuel-dependent variation in the IBD yield, dσf/dF239d\sigma_f/dF_{239}, of (1.86±0.18)×1043(-1.86 \pm 0.18) \times 10^{-43} cm2^2/fission. This observation rejects the hypothesis of a constant antineutrino flux as a function of the 239^{239}Pu fission fraction at 10 standard deviations. The variation in IBD yield was found to be energy-dependent, rejecting the hypothesis of a constant antineutrino energy spectrum at 5.1 standard deviations. While measurements of the evolution in the IBD spectrum show general agreement with predictions from recent reactor models, the measured evolution in total IBD yield disagrees with recent predictions at 3.1σ\sigma. This discrepancy indicates that an overall deficit in measured flux with respect to predictions does not result from equal fractional deficits from the primary fission isotopes 235^{235}U, 239^{239}Pu, 238^{238}U, and 241^{241}Pu. Based on measured IBD yield variations, yields of (6.17±0.17)(6.17 \pm 0.17) and (4.27±0.26)×1043(4.27 \pm 0.26) \times 10^{-43} cm2^2/fission have been determined for the two dominant fission parent isotopes 235^{235}U and 239^{239}Pu. A 7.8% discrepancy between the observed and predicted 235^{235}U yield suggests that this isotope may be the primary contributor to the reactor antineutrino anomaly.Comment: 7 pages, 5 figure

    New measurement of θ13\theta_{13} via neutron capture on hydrogen at Daya Bay

    Full text link
    This article reports an improved independent measurement of neutrino mixing angle θ13\theta_{13} at the Daya Bay Reactor Neutrino Experiment. Electron antineutrinos were identified by inverse β\beta-decays with the emitted neutron captured by hydrogen, yielding a data-set with principally distinct uncertainties from that with neutrons captured by gadolinium. With the final two of eight antineutrino detectors installed, this study used 621 days of data including the previously reported 217-day data set with six detectors. The dominant statistical uncertainty was reduced by 49%. Intensive studies of the cosmogenic muon-induced 9^9Li and fast neutron backgrounds and the neutron-capture energy selection efficiency, resulted in a reduction of the systematic uncertainty by 26%. The deficit in the detected number of antineutrinos at the far detectors relative to the expected number based on the near detectors yielded sin22θ13=0.071±0.011\sin^22\theta_{13} = 0.071 \pm 0.011 in the three-neutrino-oscillation framework. The combination of this result with the gadolinium-capture result is also reported.Comment: 26 pages, 23 figure

    A new measurement of antineutrino oscillation with the full detector configuration at Daya Bay

    Full text link
    We report a new measurement of electron antineutrino disappearance using the fully-constructed Daya Bay Reactor Neutrino Experiment. The final two of eight antineutrino detectors were installed in the summer of 2012. Including the 404 days of data collected from October 2012 to November 2013 resulted in a total exposure of 6.9×\times105^5 GWth_{\rm th}-ton-days, a 3.6 times increase over our previous results. Improvements in energy calibration limited variations between detectors to 0.2%. Removal of six 241^{241}Am-13^{13}C radioactive calibration sources reduced the background by a factor of two for the detectors in the experimental hall furthest from the reactors. Direct prediction of the antineutrino signal in the far detectors based on the measurements in the near detectors explicitly minimized the dependence of the measurement on models of reactor antineutrino emission. The uncertainties in our estimates of sin22θ13\sin^{2}2\theta_{13} and Δmee2|\Delta m^2_{ee}| were halved as a result of these improvements. Analysis of the relative antineutrino rates and energy spectra between detectors gave sin22θ13=0.084±0.005\sin^{2}2\theta_{13} = 0.084\pm0.005 and Δmee2=(2.42±0.11)×103|\Delta m^{2}_{ee}|= (2.42\pm0.11) \times 10^{-3} eV2^2 in the three-neutrino framework.Comment: Updated to match final published versio

    JUNO Conceptual Design Report

    Get PDF
    The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4σ\sigma, and determine neutrino oscillation parameters sin2θ12\sin^2\theta_{12}, Δm212\Delta m^2_{21}, and Δmee2|\Delta m^2_{ee}| to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. \sim17,000 508-mm diameter PMTs with high quantum efficiency provide \sim75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.Comment: 328 pages, 211 figure

    Improved Measurement of the Reactor Antineutrino Flux and Spectrum at Daya Bay

    Full text link
    A new measurement of the reactor antineutrino flux and energy spectrum by the Daya Bay reactor neutrino experiment is reported. The antineutrinos were generated by six 2.9~GWth_{\mathrm{th}} nuclear reactors and detected by eight antineutrino detectors deployed in two near (560~m and 600~m flux-weighted baselines) and one far (1640~m flux-weighted baseline) underground experimental halls. With 621 days of data, more than 1.2 million inverse beta decay (IBD) candidates were detected. The IBD yield in the eight detectors was measured, and the ratio of measured to predicted flux was found to be 0.946±0.0200.946\pm0.020 (0.992±0.0210.992\pm0.021) for the Huber+Mueller (ILL+Vogel) model. A 2.9~σ\sigma deviation was found in the measured IBD positron energy spectrum compared to the predictions. In particular, an excess of events in the region of 4-6~MeV was found in the measured spectrum, with a local significance of 4.4~σ\sigma. A reactor antineutrino spectrum weighted by the IBD cross section is extracted for model-independent predictions.Comment: version published in Chinese Physics

    A side-by-side comparison of Daya Bay antineutrino detectors

    Get PDF
    The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle θ13\theta_{13} with a sensitivity better than 0.01 in the parameter sin22θ13^22\theta_{13} at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.Comment: 24 pages, 36 figure
    corecore